Current Sensing - Flux-Gate Transducers - DCT 400A Transducers
Features:
High Accuracy over high bandwidth.
- Very low output noise and offset drift.
- Negligible insertion losses.
- High immunity to interference.
- Overload Capability.
- Excellent linearity.
General Data:
- Operating Temperature: -20 to 70 ºC
- Storage Temperature: -20 to +85 ºC
- Weight: 400g
- Primary Diameter Hole: 25mm
- Basic Insulation (Between Primary and Measurement Current): 3500V AC 50Hz 1'
Accuracy:
- Accuracy at Ip (T=25ºC): < 0.1%
- Linear Error ( Beetwen 100 to 400 A) Vcc = ±15V, Rb = 1.8 Ohm: < 5 ppm
- Linear Error ( Beetwen 10A to 100A ) Vcc = ±15V, Rb = 10 Ohm: < 10 ppm
- Linear Error ( Beetwen 0.1 to 10A ) Vcc = ±15V, Rb = 33 Ohm: < 50 ppm
- Offset Current: 5uA Max
- Offser Current Temperature Drift: < 5 ppm/ºC
- Time Response ( 10% to 90% of Ip): <1us
- di/dt Followed Accurately: > 100A/us
- Frequency Bandwidth ( Ip = 10A DC): DC to 100kHz ( -3dB )
Output Inputs Connector Information:
- Connector: DB-9 Standard Type (Female)
- Fault Operation Condition (Led Power OFF): Ip > 120 %
- Maximum Switching Current (pins 3 to 8 and pin 3 to 7): 2A
- Maximum Switching Voltage (pins 3 to 8 and pin 3 to 7): 30 VDC/120 VAC
- Compensation Winding Maximum Resistance (T = 50ºC): 30 Ohm RC
- Length Two Wire Cable to R burden (Connected beetwen pin 1 to 6): 50cm (Typical)
Applications:
- Precise and high stability inverters.
- Energy measurements.
- High Precision Power Supplies.
- Feed back element in high performance gradient amplifiers for MRI.
- Medical Equipment.
According to:
- UNE EN 50178
- UNE EN 50155